APC by Schneider Electric NetShelter PDU

APC by Schneider Electric NetShelter PDU – Switched – IEC 60309 20A 3P+N+PE – 24 x IEC 60320 C13/C15, 24 x IEC 60320 C13/C15/C19/C21 – 20 A – 230 V AC Input – 240 V AC Output – 0U – Rack

  • 230 V AC input voltage for optimal performance with maximum usability
  • 240 V AC output voltage for better reliance and maximum usability
  • IEC 60309 20A 3P+N+PE plug/connector type for better, dependable connectivity and desired power output
  • IEC 60320 C13/C15/C19/C21 receptacle type to ensure maximum dependability and optimal performance
  • Three Phase phase PDU provides dependable power output with maximum efficiency
  • With a built-in digital current meter avoid potential overloads via switched PDUs

Out of stock

£1,975.82 Exc. VAT / £2,370.98 Inc. VAT

Condition: Brand New & Sealed. Sourced through manufacturer’s authorised UK channels.

Manufacturer's Part Code: APDU10250SM Categories , , UPC/EAN Code: 0731304439707

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2″ wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today’s high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

General Information

Product Type PDU
Manufacturer Part Number APDU10250SM
Manufacturer Website Address http://www.schneider-electric.com
Marketing Information

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Manufacturer Schneider Electric SA
Product Name NetShelter 48-Outlets PDU
Product Line NetShelter
Brand Name APC by Schneider Electric

Power Description

Input Voltage 230 V AC
Output Voltage 240 V AC
Input Current 20 A
Input Voltage Range 200 V AC - 240 V AC
Power Rating (VA) 11.50 kVA
Power Rating (Watt) 11.50 kW

Physical Characteristics

Weight (Approximate) 7.70 kg
Form Factor Rack
Rack Height 0U
Height 1490 mm
Width 56 mm
Depth 75 mm
Product Color Black

Technical Information

Plug/Connector Type IEC 60309 20A 3P+N+PE
Phase Three Phase
Receptacle Type IEC 60320 C13/C15/C19/C21
PDU Type Switched
Receptacle Detail 24 x IEC 60320 C13/C15